Logging Cable

Logging Cable (also known as Wireline) serves as the critical link between surface recording equipment and downhole logging tools. 

It is responsible for supplying power to downhole instruments and transmitting high-precision formation data in real-time, while also acting as the primary load-bearing member to support the weight of the tool string. 

Our logging cables feature a dual-layer, counter-helically wound high-strength galvanized steel wire construction, ensuring exceptional tensile strength and superior torque balance.

Components Material Options Technical Functions
Conductor
Tinned Copper / Silver-plated Copper
Core for signal and power; plating prevents vulcanization and enhances conductivity.
Insulation
PP, ETFE (Tefzel), PFA (Teflon)
High dielectric strength; ensures signal stability in environments up to 315°C (600°F).
Shielding & Filler
Copper Braid / Conductive Plastic
Eliminates EMI between conductors to ensure high-frequency data integrity.
Inner Armor
Galvanized Steel Wires
Primary load-bearing layer; counter-helically wound to cancel torque under tension.
Outer Armor
IPS, GEIPS, SS, Monel
Outermost protection; endures wellbore abrasion and provides ultimate breaking strength.

Open-hole & Cased-hole Logging

Used to acquire physical parameters such as resistivity, sonic, and radioactivity.

 

Perforating Services

Deploys perforating guns and provides precise triggering for reservoir connectivity.

 

Downhole Intervention & Maintenance

Used for setting bridge plugs, packers, or operating downhole camera systems.

 

HPHT Environments

Specialized high-temperature insulation (Teflon/PFA) solutions for ultra-deep wells.

Parameter Typical Range / Options
Cable Diameter
Available in standard sizes including 3/16″, 7/32″, and 15/32″ (4.7mm – 11.8mm).
Conductor Count
Versatile configurations featuring 1, 3, or 7 conductors.
Max. Breaking Strength
Ranges from 15 kN to over 100 kN (depending on diameter and material).
Temperature Rating
Scalable solutions for 150°C (302°F), 232°C (450°F), and 315°C (600°F).
Capacitance
Optimized pF/m ratings to ensure long-distance signal transmission integrity.

Hybrid Signal Conductors

Integration of Fiber Optic units within the cable core for distributed temperature sensing (DTS) or high-speed acoustic data telemetry.

Anti-Cage/Anti-Birdcage Design

Specialized winding tensions and lubrication coatings to prevent armor deformation during high-speed deployment or rapid pressure changes.

Continuity & Electrical Validation

Full-length testing under simulated pressure loads prior to delivery.

 

Armor Integrity Testing

Rigorous salt spray and flex-fatigue tests on armor wires to ensure corrosion resistance.

 

Mechanical Stability

Verification of torque balance and elongation properties to maintain stable performance downhole.